If this relates to a live job, our heat pump survey page explains what we capture before design.
A heat loss calculation estimates how much heat a room or whole dwelling needs on a cold design day. That result then shapes emitter sizing, flow temperatures, and whether a proposed system looks reasonable before installation starts.
What goes into the calculation
| Input | Why it matters |
|---|---|
| Room dimensions | They define the heated volume and the area of the building elements losing heat. |
| Walls, floor, roof, and glazing | Different constructions lose heat at different rates. Assumptions here can move the answer materially. |
| Ventilation and infiltration | Air leakage and ventilation losses can be material, especially in older or altered homes. |
| Internal design temperature | Bedrooms, bathrooms, and living rooms are not always built to the same target temperature. |
| Outside design temperature | The design day assumption changes with location and standard. |
Why room-by-room outputs matter
A whole-house figure may tell you the rough size of the heat source. It does not tell you whether the box room, bathroom, or north-facing lounge is the place that will underperform. Room-by-room results are what make emitter decisions usable rather than theoretical.
Worked example: one room, one assumption change
| Example room | Initial assumption | Revised assumption | Practical effect |
|---|---|---|---|
| 1950s front bedroom with two external walls | Window treated as later double glazing | Window confirmed as older failed double glazing | The room heat loss rises, which can change the radiator choice even if the whole-house figure barely moves. |
Where calculations go wrong
- Assumptions are made but never written down.
- Extensions or altered rooms are treated as if they match the original house.
- Emitter decisions are made from a headline figure rather than room outputs.
- Unknown constructions are guessed too optimistically.
- The calculation is presented without any supporting evidence from site.
What a usable output should show
Alongside the total heat loss, the report should show the room list, assumptions and temperatures. It should also flag where construction could not be seen fully and the designer or installer needs to review an assumption.
What this means for homeowners
If you receive very different heat-pump proposals for the same house, compare the property assumptions as well as the equipment brands. Different assumptions can change the result, so ask to see what each calculation is based on.
Sources
For the survey inputs behind these numbers, read heat loss inputs: measurements and assumptions.